IxANVL 8.10 EA release introduces the MPLS-TP-Y1731, MPLS-TP-IETF and MPLS-TP APS protocol conformance test suites. A few outstanding bugs reported since the previous release has also been fixed in this release.
Follows a brief description of the newly introduced test suites:
- MPLS-TP-Y1731 - This test suite is based on the following MPLS-TP specifications and contains about 80+ test cases.
- RFC 5586 (GACH)
- draft-bhh-mpls-tp-oam-y1731-06.txt
- ITU-T-REC Y.1731-200605-l
- MPLS-TP-IETF - This test suite is based on the following MPLS-TP specifications and contains about 200+ test cases.
- RFC 5586 (GACH)
- draft-ietf-mpls-loss-delay-01
- draft-ietf-mpls-tp-on-demand-cv-02
- draft-ietf-mpls-tp-cc-cv-rdi-03
- MPLS-TP-APS - This test suite is based on the following MPLS-TP specifications and contains about 130+ test cases.
- G.8031_Y.1342-2006-06
- This release also introduces DUT Composer and Windows 7 32-bit platform support for IxANVL. DUT Composer is a Device configuration interface for users which enables replay of manual configuration performed by users. This feature is an alternative to expect based automation. Users manually configure the DUT and ANVL replays back the configuration session while running tests.
- This release also introduces sock5 support for Linux based VNIC, which enables users to run IxANVL from a PC, connected to a chassis in a different subnet.
Product Compatibility
IxANVL 8.10 EA requires IxOS 5.70 GA or IxOS 6.10 EA, or a later version of IxOS 5.70 GA or 6.10 EA, if operating with VNIC (v3.10) on Ixia load modules.
NOTE: To ensure proper operation of a client with supported IxOS versions, prior to installing this application release you must un-install all previous versions of Ixia applications, Ixia StatEngine, Ixia StatEngine PCPU packages and IxOS. After the un-installations are complete, the client must be rebooted.
For additional product compatibility information please refer to the following online utility. An Ixia website account is required before accessing.
http://www.ixiacom.com/support/product_compatibility_matrix/
IxANVL Workstation Requirements
CPU: | 32-bit Pentium 4 or better | ||||||||
---|---|---|---|---|---|---|---|---|---|
RAM: | 2GB or more | ||||||||
Disk: | 750MB Free or more | ||||||||
OS: |
|
Supported Test Interfaces
Network interface cards directly attached to a Linux or Windows PC:
- Ethernet 10/100
- Gigabit Ethernet
- Async serial
- Sync serial
- T1/E1
- PPPoE
Ixia Load Modules (port CPU required) accessed via Virtual Network Interface Card (VNIC):
- 10/100/1000 Ethernet Modules:
- LM100TXS8
- LM100STSXS2
- LM1000STXS4
- OLM1000STXS24
- LM1000STXR4
- LSM1000XMS12-01/LSM1000XMSR12-01
- ALM1000T8
- LSM1000XMV16-01/LSM1000XMV12-01/LSM1000XMV8-01/LSM1000XMV4-01
- LSM1000XMVR16-01/LSM1000XMVR12-01/LSM1000XMVR8-01/LSM1000XMVR4-01
- ASM1000XMV12X-01, non-Aggregate Mode
- ELM1000ST2
- LSM1000XMVDC16
- 10G Modules:
- LSM10G1-01/LSM10gL1-01
- LSM10GXL6-01/LSM10GXL6-02
- LSM10GXM3-01/LSM10GXMR3-01
- MSM10G1-01
- LSM10GXM3-01/LSM10GXMR3-01
- LSM10GXM4-01/LSM10GXMR4-01
- LSM10GXM8-01/LSM10GXMR8-01
- LSM1000XMV8-01/LSM1000XMVR8-01
- LSM1000XMV12-01/LSM1000XMVR12-01
- LSM10GXM2XP-01/LSM10GXMR2-01
- LSM10GXM4XP-01
- LSM10GXM8XP-01
- LSM10GXM8-01/LSM10GXM8S-01
- LSM10GXM8NG-01
- Acceleron
- POS/ATM Modules:
- MSM2.5G1-1
- MSM10G1-01
- LM622MR
Release Notes [ click here ]
If you would like to upgrade your current IxANVL software, please send an email to our Support Department ([email protected] ) and be sure to include your registration number.
IxANVL EULA's
Additional links