IxANVL 8.65 EA is an "Early Adopter" release. It provides enhancements for the test suites of Openflow1.3 and CE2.0. It also includes the bug fixes since the previous release.
The following is a brief description of the enhanced test suites:
- Enhanced Suites
- OpenFlow 1.3: This test suite is based on the OpenFlow Switch Specification Version 1.3.2 (Wire Protocol 0x04). 126 new test cases are added.
- CE2.0: This test suite is based on Carrier Ethernet 2.0 Test Plan. 58 additional test cases for ETREE and 88 test cases for EACCESS are added.
IxOS Compatibility
IxANVL 8.65 EA requires IxOS 6.60 EA Patch1 or higher if operating with VNIC (v3.60) on the Ixia load modules.
NOTE: To ensure proper operation of a client with supported IxOS versions, prior to installing this application release you must un-install all previous versions of Ixia applications, Ixia StatEngine, Ixia StatEngine PCPU packages and IxOS. After the un-installations are complete, the client must be rebooted.
Application Compatibility
NOTE: When you are using one or more of the applications below on a single chassis configuration, please use the correct application versions so they align to a common version of IxOS.
Application | IxOS 6.60 EA Patch1 |
---|---|
IxANVL | 8.65 EA |
IxAutomate | 7.40 GA SP3 |
IxLoad | 6.40 EA |
IxN2X | 7.60 GA |
IxNetwork | 7.20 EA Patch1 |
IxNetwork-FT | 7.20 EA Patch1 |
IxVPN | 3.00 GA SP3 Patch16 |
Licensing | 3.00 EA SP5 |
VNIC | 3.60 EA |
For additional product compatibility information please refer to the following online utility. An Ixia website account is required before accessing.
Ixia Product Compatibility Matrix
IxANVL Workstation Requirements
- CPU: 32-bit 2 GHz Pentium or better
- RAM: 2GB or more
- Disk: 1.5GB free or more
Windows OS:
Microsoft Windows XP Professional 32-bit, Windows 2003 Server 32-bit, Windows 7 Enterprise 32-bit, Windows 7 Professional 32-bit, Windows 2008 Server Enterprise SP2 32-bit (in single user mode), Windows 7 Professional 64-bit, Windows 2008 Server R2 standard 64-bit.
(IxANVL supports the US English versions of the Windows OS. Although, IxANVL may run on other versions of Windows OS, they are not officially supported by Ixia. If you attempt to install or run IxANVL on any version of Windows OS other than the U.S. English versions, the IxANVL installation or operation may fail.)
Linux OS:
CentOS5.9 (32 bit) with kernel 2.6.18-348.el5, RHEL5.9 (32 bit) with kernel 2.6.18-348.el5, Centos 5.3 with kernel 2.6.18-128.e15xen
Important Note:
Java has a known caveat that requires an extra rpm file, xorg-x11-deprecated-libs-6.8.2-31.i386.rpm, that sometimes is not installed by default on an RHE 5.0 machine. As the IxANVL installeris a Java-based application, it is required that this file be installed in order to function normally. Please refer to the Linux installation notes below for a workaround to fix this problem.
Ixia Chassis OS:
IxOS 6.50 GA or 6.60 EA.
Supported Test Interfaces
Network interface cards directly attached to a Linux or Windows PC
- Ethernet 10/100
- Gigabit Ethernet
- Async serial
- Sync serial
- T1/E1
- PPPoE
Ixia Load Modules (port CPU required) accessed via Virtual Network Interface Card (VNIC)
10/100/1000 Ethernet Modules:
- LM100TXS8
- LM100STSXS2
- LM1000STXS4
- OLM1000STXS24
- LM1000STXR4
- LSM1000XMS12-01/LSM1000XMSR12-01
- ALM1000T8
- LSM1000XMV16-01/LSM1000XMV12-01/LSM1000XMV8-01/LSM1000XMV4-01
- LSM1000XMVR16-01/LSM1000XMVR12-01/LSM1000XMVR8-01/LSM1000XMVR4-01
- ASM1000XMV12X-01, non-Aggregate Mode
- ELM1000ST2
- LSM1000XMVDC16
- LSM1000XMSP12
10G Modules:
- LSM10G1-01/LSM10gL1-01
- LSM10GXL6-01/LSM10GXL6-02
- LSM10GXM3-01/LSM10GXMR3-01
- MSM10G1-01
- LSM10GXM3-01/LSM10GXMR3-01
- LSM10GXM4-01/LSM10GXMR4-01
- LSM10GXM8-01/LSM10GXMR8-01
- LSM1000XMV8-01/LSM1000XMVR8-01
- LSM1000XMV12-01/LSM1000XMVR12-01
- LSM10GXM2XP-01/LSM10GXMR2-01
- LSM10GXM4XP-01
- LSM10GXM8XP-01
- LSM10GXM8-01/LSM10GXM8S-01
- LSM10GXM8NG-01
- Acceleron
40G/100G Modules:
- Xcellon-Mulits - XM100GE4CXP+FAN
- HSE 40GE QSFP1-01
- FlexFE40QP
- LAVA AP40/100GE 2P
POS/ATM Modules:
- MSM2.5G1-1
- MSM10G1-01
- LM622MR
Release Notes [ click here ]
If you would like to upgrade your current IxANVL software, please send an email to our Support Department and be sure to include your registration number.
IxANVL EULA's